Auckland, New Zealand. 0800 2 R8HOME

September 12, 2023 Comments Off

  Textured coating in ceiling of a 1962 house is suspected to contain Asbestos. Samples taken and sent to laboratory and confirmed to contain Asbestos.

September 7, 2023 Comments Off

During subfloor inspection, leak observed from the shower trap which is soaking wet the floorboard, bearer and joists around and causing rot. It was insisted that the leak must be fixed by a

March 23, 2021 Comments Off

Wet / rotting batten near roof ridge caused by roof leak. It was found the trapezoidal metal roof had the ridge flashing lifted up at this place.

January 1, 2021 Comments Off

A house where most of the windows were leaking at bottom corners, detected by moisture meter. It was recommended to conduct further investigation by a qualified weathertightness surveyor.

January 1, 2021 0 Comments

On taking moisture meter testing under the vanity, high moisture meter readings observed all the way way from the sewer pipe penetration to wall down to the bottom plate. It needs repair by

January 1, 2021 Comments Off

Roof truss was cut to accommodate the fireplace chimney (that was removed later). Timber truss cannot be cut like this as this affect the structural stability of the roofing. Recommended this be repaired

January 1, 2021 Comments Off

The roof end to wall junction of a 2002 built house with direct fixed EIFS cladding lacks kickout flashing and the metal gutter is buried in to the cladding which is a high